logo
家へ > 製品 > イオン クロマトグラフィーの器械 >
220V 50Hz Power Supply Ion Chromatography Instrument with Optional Detectors

220V 50Hz Power Supply Ion Chromatography Instrument with Optional Detectors

Place of Origin:

Anhui, China

ブランド名:

Wayeal

証明:

CE

Model Number:

IC6600

連絡 ください
引金 を 求め て ください
製品詳細
エルーエント濃度範囲:
KOH、MSA-0.1・100.0mM
定性的再現性:
≤0.1%
電源:
220V,50~60Hz
コラム容量:
2個 250mm と 150mm
ポンプ圧力:
0~42Mpa
注射位置:
120の位置
量的な反復性:
≤0.5%
注射量:
10uL~4000uL
支払いと送料の条件
Minimum Order Quantity
1 Unit
価格
Negotiate
Packaging Details
Wooden Case
Delivery Time
35 days
Payment Terms
T/T
Supply Ability
30 Units/Month
製品説明

Introduction of IC6600 Ion Chromatography Instrument

The Ion Chromatography Instrument is an advanced analytical device designed to deliver exceptional performance and reliability in ion detection and quantification. Engineered with precision, this instrument offers outstanding qualitative repeatability, ensuring consistent and accurate results with a variability of less than or equal to 0.1%. This high level of repeatability makes the Ion Chromatography Instrument an ideal choice for laboratories requiring dependable data for research, quality control, and routine analysis.

Technical Parameters of IC6600 Ion Chromatography Instrument

Product Name Multifunctional Ion Chromatography
Model IC6600
Working power 220V, 50Hz
Ambient temperature 10-40°C
Relative humidity 20-85%
Qualitative repeatability ≤0.1%
Quantitative repeatability ≤0.5%
Pump flow rate range 0.001~12.000mL/min
Pressure resistance of pump head 0-40MPa
Flow setting error <0.1%
Flow stability <0.1%
Pressure display accuracy 0.001MPa
Pressure plusation <0.25%
Conductivity detector  
Baseline noise ≤0.03%FS
Baseline drift ≤0.1%FS
Mini detectable concentration (Cl): ≤0.0001μg/mL
Mini detectable concentration (Li): ≤0.00005μg/mL
Mini detectable concentration (NO3): ≤0.001μg/mL
Mini detectable concentration (Na+): ≤0.001μg/mL
Mini detectable concentration (Ca2+): ≤0.005μg/mL
Conductivity cell volume ≤0.4μL
Conductivity detection range 0-45000μS/cm
Detector resolution 0.00238nS/cm
Conductivity cell temperature setting error ±0.01°C
Conductivity cell temperature display resolution 0.001°C
Conductivity cell temperature control range Detector temperature zone temperature +5°C-65°C
Conductivity cell temperature control stability 0.05°C
Conductivity cell temperature setting value error 0.1°C/h
Ampere detector  
Type Thin-layer structure, automatic range
Driving voltage range -2.0V-2.0V
Drive voltage resolution 0.001V
Output signal range

Integral mode: 50pc-200uC

DC mode: 1pA-74μA

Noise

Integration mode<30pC

DC mode<5pA, DC mode static noise<1pA

Cell material Titanium
Pool volume <0.2μL
Maximum pool pressure 0.7MPa
Minimum detectable concerntration I-0.001μg/mL
Minimum detectable concerntration fructose 0.01μg/mL
UV Detector  
Wavelength indication error 0.1nm
Wavelength repeatability 0.1nm
Mini detectable concentration BrO3-0.0005μg/mL
Mini detectable concentration CrO42-0.001μg/mL
Qualitative repeatability ≤0.05%
Quantitative repeatability ≤0.3%
Suppressor  
Dead volume 50μL
Inhibition capacity 170ueq/min
Pressure resistance 3MPa
Column oven  
Temperature range Room temperature +5°C~70°C
Temperature control stability 0.1°C/h
Error of temperature setting value 0.05°C
Autosampler  
Number of samples ≥120 (1.5ml sample bottle)
Temperature 4~30°C
Linear >0.999
Cross-contamination <0.01%

 

 

 

問い合わせを直接私たちに送ってください.

プライバシーポリシー 中国 良質 ヘリウムの漏出探知器 提供者 著作権 2022-2025 Anhui Wanyi Science and Technology Co., Ltd. すべての権利は保護されています.